18015413905 18015413906
   
ADD: Suzhou Xiangcheng industrial director Wong Tai Ping Road 90
TEL:18015413905 18015413906
FAX:0512-65623905
E-mail:salesjsjzyx@163.com
WEB:http://www.jsjzyx.com
  HERE IS >>  Special processing machine             
  P14AWashing machine

 

Jun Ze P Series Medical Film Processor 

JZ-P14

JZ-P14A

JZ-P17

JZ-P17A

P14、P14A、P17Schematic diagram of

P17ASchematic diagram of

 

 

 

  Latest generation JZ-P14/P17 is a desktop suitable for small and medium-sized washing the washing machine, the operation is very simple. High speed and efficiency, and precision computer-controlled, beautiful overall injection shape. It can be widely used in medical imaging centers, hospital clinical diagnosis, private clinics, animal hospitals, laboratories, and mobile vehicle. Schematic diagram of

 

 

feature:

 

 

 

1.Side panel design

  The side panels with detachable design, user at a glance; maintenance, maintenance is more convenient. Side panel design

 

 

 

2.Reliable performance

  Reliable microprocessor control procedures to ensure product quality. Further improve the temperature control of the computer, the accuracy of the speed control, whether you used continuously for long, it can easily do the job.

 

 

3.Control Panel

                                                      

 
Knob to adjust the temperature and speed, relying on the film transport sensor can automatically complete the whole process of developing, fixing, washing and drying.

 

 

 

 

4.New send-chip board

  Feeding board with a special set of new material (Japan Ling Yake force plate) to ensure that the film in the process of flushing non-stick film, thus ensuring the quality of the film wash; to avoid the film of a metal material to produce rust and static and impactrinse quality.

5.New PTC heating block

  Using the new PTC heating instead of the previous heating wire, to ensure uniform drying hot air, film drying effect, and significantly longer service life.

6.Change the drain pipe location; bold washing the circulation line    The past, I produced the P series washing machine, reference Brooklyn Tektronix, Germany washing machine drain pipe design in the front of the washing machine drain pipe; users accustomed to the rear of the washing machine operation,avoid sending films dirty clothes. Similarly, this design is easy to make a washing machine to wash films control is not good washing water flow resulting in significant, fixing drug contamination. Drain pipe on the back of the washing machine for the above problems our technical department, bold washing the circulation line. Change the drain pipe location; bold washing the circulation line

 

  

7.The protection of the microcomputer design

     Baffle design to eliminate the significant, the fixing liquid steam erosion of the circuit board, thereby extending its life, this design also greatly facilitates the maintenance engineer.

 

 

8.The drive roller group

  DuPont materials pouring the forming roller, acid, alkali, will not easily expand or crack, roller lifetime warranty. High strength dense arrangement of the type of roller to ensure secure transmission of the film of any size, and effectively prevent liquid splash.

 

 

9.Into the chip sensing probe

   Using imported micro switch as the film advance sensor, reliable, simple and guaranteed.

10.The use of plastic film clips

    To avoid rust and static electricity generated by the use of metal materials, greatly improving the quality of the film wash.

 

 

11.Increase the drug trough cover

   Developing and fixing slot cover design to avoid cross-contamination of liquid to effectively prevent the natural oxidation of the liquid, to extend the usage time of the liquid.

 

 

 

12.Advanced heating system

  The unique design of the heating system does not contact with the liquid, greatly extending the heating rods life.

+

 

 

13.Two-body fluid system

  Automatic the catamaran supplement pump can be based on the number of washing their own fresh liquid, so that the working fluid is always kept fresh.

 

 

14."C "card

     According to user response when cleaning washing machine roller group, "C" card is easy to fall into gear, the phenomenon of the card. According to this phenomenon, the technology sector, specializing in the import reinforced nylon material, and change its shape to solve problems, thus ensuring the safe operation of the film.

15.Automatic circulation system

  Automatic circulation system allows the liquid concentration is consistent.

 

 

Jun Ze P Series comes standard with:

 

 

 

1.Developing fixing synchronization heating system
2.Developing fixing washing independent circulatory system
3.Developing fixing synchronization complement system
4.Electromagnetic valve-regulated water, water-saving system
5.Professional conical duct drying system
6.Mechanical sensing feed-chip system
7.The DKM electronic speed control energy-saving system

 

 

Technical parameters

 

 

P-14 Technical parameters

Max processing width

350mm(14")

Wash Specification

Maximum wash width of 14 inches, minimum wash size 3 × 3 × 4 inches

Processed film variety

X-ray, CT, MRI and other medical film

Flush the whole process time

105/135/165s,±1s

Development time adjustment

25/35/45s

Hourly flushing volume

Developing 25 seconds: 14 x 17-inch and 80

Temperature regulation

Liquid:28℃~37℃    Drying:45℃~65℃(Automatic adjustment

Liquid supplement method

, Automatic replenishment and manual complement each rinse 0.5 m2 supplementary time

Supplement the amount of adjustment

20ml~200ml

Flushing procedure

Developing, fixing, washing, drying time auto-complete

Liquid capacity

Ceramic heating device
Developing 5.2 liters, 5.2 liters of fixing

Washed control

Automatically controlled by a solenoid valve, to see the piece flush water, no piece rinse off

Power supply

220V/50Hz、8.8A;  Power:2KW

Pipes interface

3/4Inch

Volume

770mm(Long)×590mm(Wide)×420mm(High)  (Not even the chassis)

Weight

50Kg±1Kg

P-14A

Max processing width

350mm(14")

Wash Specification

Maximum wash width of 14 inches, minimum wash size 3 × 3 × 4inches

Processed film variety

X-ray, CT, MRI and other medical film

Flush the whole process time

90s~360s,±1s

Development time adjustment

20s~70s

Hourly flushing volume

Developing 20 seconds: 14 x 17-inch 120

Temperature regulation

Liquid:20℃~40℃    Drying:20℃~70℃

Liquid supplement method

, Automatic replenishment and manual complement each rinse 0.5 m2 supplementary time

Supplement the amount of adjustment

20ml~500ml

Flushing procedure

Developing, fixing, washing, drying time auto-complete

Liquid capacity

5.5 liters of the developing, fixing 5.5 l

Washed control

Automatically controlled by a solenoid valve, to see the piece flush water, no piece rinse off

Power supply

220V/50Hz、12A;  Power:2.64KW

Pipes interface

3/4Inch

Volume

770mm(Long)×590mm(Wide)×420mm(High)  (Not even the chassis)

Weight

50Kg±1Kg

P-17

Max processing width

450mm(17")

Wash Specification

Maximum wash width of 14 inches, minimum wash size 3 × 3 × 4inches

Processed film variety

X-ray, CT, MRI and other medical film

Flush the whole process time

105/135/165s,±1s

Development time adjustment

28/36/44s

Hourly flushing volume

Developing 28 seconds: 14 x 17-inch 110

Temperature regulation

Liquid:28℃~37℃   Drying:45℃~65℃(Automatic adjustment

Liquid supplement method

, Automatic replenishment and manual complement each rinse 0.5 m2 supplementary time

Supplement the amount of adjustment

20ml~200ml

Flushing procedure

Developing, fixing, washing, drying time auto-complete

Liquid capacity

Developing 8 l 8 l, fixing

Washed control

Automatically controlled by a solenoid valve, to see the piece flush water, no piece rinse off

Power supply

220V/50Hz、10A;  Power:2.2KW

Pipes interface

3/4Inch

Volume

770mm(Long)×690mm(Wide)×420mm(High)  (Not even the chassis)

Weight

60Kg±1Kg

P-17A

Max processing width

450mm(17")

Wash Specification

Maximum wash width of 14 inches, minimum wash size 3 × 3 × 4inches

Processed film variety

X-ray, CT, MRI and other medical film

Flush the whole process time

90s~360s,±1s

Development time adjustment

20s~70s

Hourly flushing volume

Developing 28 seconds: 14 x 17-inch 240

Temperature regulation

Liquid:20℃~40℃    Drying:20℃~70℃

Liquid supplement method

, Automatic replenishment and manual complement each rinse 0.5 m2 supplementary time

Supplement the amount of adjustment

20ml~500ml

Flushing procedure

Developing, fixing, washing, drying time auto-complete

Liquid capacity

Developing 12.5 liters, 12.5 liters of fixing

Washed control

Automatically controlled by a solenoid valve, to see the piece flush water, no piece rinse off

Power supply

220V/50Hz、13A;  Power:2.86KW

Pipes interface

3/4Inch

Volume

770mm(Long)×690mm(Wide)×450mm(High)  (Not even the chassis)

Weight

70Kg±1Kg

 

                 

Tel: 18015413905 18015413906 address: Suzhou Xiangcheng industrial director Wong Tai Ping Road 90 Copyright: Jun Ze Suzhou imaging equipment Limited professional R & D, production, sales of medical X ray film washing machine, washing machine, full automatic washing machine, washing film machine, LED medical film observation lamp, liquid crystal film viewing lamp, ultra-thin film viewing lamp industrial film viewing lamp, such as medical imaging equipment ... ...
ICP:110470688 COPYRIGHT:Jun ze Image Equipment Suzhou Co., Ltd    Technical support:360全景展示